GLORYSmart Safe Client

Preparing the DE-70

Check the DE-70 and its cable before installing the Smart Safe Client.

The DE-70 talks to the computer through a serial cable. For the Smart Safe Client to find it and drive it, the DE-70 must use the values on this page. Check them one by one: if any of them is different, change it on the DE-70.

Before you start

The DE-70 must be turned on, with no error messages on its screen and with the reject tray empty.

1. Protocol A

The Smart Safe Client only talks to a DE-70 with protocol A. Confirm this before anything else:

On the DE-70, open USER MENU › INFORMATION.

Tap the MACHINE tab.

The TYPE line must say DE-70A.

INFORMATION screen of the DE-70, MACHINE tab, with the TYPE line showing DE-70A

If TYPE does not say DE-70A

The DE-70 does not have protocol A and the Smart Safe Client will not find it, even if everything else is right. This cannot be fixed on the computer: open a ticket with a photo of this screen.

2. Communication

Communication is checked in the RAS, the DE-70's service menu:

On the DE-70's main screen, press the keys F1, F4, F2 and F3, in that order (they are to the right of the screen). The RAS opens.

Go to SERVICE › MACHINE SETTINGS › INTERFACE. If you do not see an option, tap the › arrow on the right: some RAS screens have more than one page.

SERVICE asks for a key combination

The SERVICE menu only opens with a specific key combination, which is not in this documentation. If you do not know it, ask a GLORY technician or a trained technician from the distributor (dealer) for help. To reach GLORY, open a ticket

Confirm these values:

On the screenCorrect value
PORTCOM (the serial port)
BAUD RATE9600
DATA BIT7
STOP BIT1
PARITY BITEVEN (even parity)
INTERFACE screen in the DE-70's RAS: PORT COM, BAUD RATE 9600, DATA BIT 7, STOP BIT 1 and PARITY BIT EVEN

Bits, parity and stop bit are not changed on the computer

The Smart Safe Client always uses 7 bits, even parity and 1 stop bit. If the DE-70 has other values, change them on the DE-70.

3. Operation mode

The Smart Safe Client is the one that tells the DE-70 when to count and when to store the notes. For that, the DE-70 must wait for its orders. Check it in the same RAS as in step 2:

Go to SERVICE › MACHINE SETTING 2. SERVICE asks for the same key combination as in step 2.

Confirm these values:

On the screenCorrect value
LOCAL MODEOFF
START MODEMANUAL
AUTO ESCROWOFF

Do not change the other options on that screen.

MACHINE SETTING 2 screen in the DE-70's RAS: LOCAL MODE set to OFF, START MODE set to MANUAL and AUTO ESCROW set to OFF

With other values, the DE-70 counts and stores on its own

The DE-70 starts counting as soon as it receives the notes and stores them in the cassette without waiting for the Smart Safe Client. In the deposit, Finalize — store in safe does not appear and, if the operator cancels, the notes are already in the cassette: they do not go back to the customer.

4. Cassette capacity

The DE-70 saves how many notes fit in its cassette (for example 5000, 5500 or 10000). The Smart Safe Client reads that number from the DE-70 and does not allow deposits if it cannot find it.

Confirm it in the RAS (see step 2 to get in), under MACHINE SETTING › STORAGE LIMIT: it is the number of notes that fit in the cassette (in the picture, 5000). It must be the real capacity of the installed cassette.

There are two different MACHINE SETTING menus

This MACHINE SETTING is on the main screen of the RAS. The ones in steps 2 and 3 are different: they are inside SERVICE.

MACHINE SETTING screen in the DE-70's RAS, with STORAGE LIMIT at 5000

5. Currency

The DE-70 only counts notes of the currencies loaded on it (for example, dollars). Confirm that the customer's currency is loaded: in USER MENU › INFORMATION, CURRENCY tab, you see the currencies the DE-70 has. It is the same screen as in step 1 on a different tab.

If the customer's currency is not there, the DE-70 cannot count those notes and this cannot be fixed on the computer: open a ticket with a photo of that tab.

Later, when you add the DE-70 in the Smart Safe Client, the Fetch from device button shows the currencies the DE-70 has.

6. Cable

Plug the cable into the DE-70's serial port (9-pin connector, RS-232).

Plug the other end into the computer. If the computer has no serial port, use a USB-to-serial adapter.

Do not use the DE-70's USB port: the Smart Safe Client connects through the serial port.

7. Exit the RAS and go back to the main menu

When you finish, exit the RAS and leave the DE-70 on the main menu (the counting screen).

The DE-70 only connects from the main menu

The DE-70 only talks to the Smart Safe Client when it is on the main menu (the counting screen). If it stays in the RAS or in another menu, the Smart Safe Client does not find it.

Front of the DE-70 on the main menu: the counting screen with the currency, MIXED mode and the counters at 0, and the F1 to F4 keys on the right

8. Confirm the port on the computer

With a USB adapter, the port shows up as /dev/ttyUSB0 (see Folders and paths)

The computer's user needs permission to use the port. The Smart Safe Client installer gives it on its own. If the Smart Safe Client still says the port is busy, open a terminal and run (see usermod and reboot):

sudo usermod -aG dialout $USER
sudo reboot

Next step

The DE-70 is ready. Now, the computer:

On this page