GLORYSmart Safe Client

Peripherals

The sensor board, the UPS, the shutter and the Cash Infinity's OCR that are not found, do not answer or stop an operation, and the amount read from the point of sale.

The Smart Safe Client works only with these models: the ACEN BMZ103-RC sensor board, the SMS and Ragtech NSV600 UPS, the Guillotine and Glory Vertex shutters, and a video capture adapter (HDMI → USB) for the OCR of the Cash Infinity. How to set them up is in Peripherals

The first check is always the same: open the Maintenance screen on the device and tap the Peripherals tab. Each peripheral must say Connected.

A peripheral that does not answer stops the operations

A peripheral saved with Fitted and in use ticked that stops answering blocks the operations of its device until it answers again; a silent UPS blocks those of every device. The Smart Safe Client tries to connect it again on its own every 15 seconds. A peripheral that is not set up blocks nothing.

Setting it up: the port and Find automatically

ProblemWhat to do
Nothing answered on any port.Check that the peripheral is on and that its cable and USB adapter are connected. On Linux, if the Smart Safe Client was installed a moment ago, restart the computer first: the permission to use the serial ports takes effect at the next start, as usermod explains. Then tap Find automatically again.
Nothing could be asked on …: these ports are already assigned here to a device or peripheral. A serial port has a single owner.Each port serves one thing only, and that one already belongs to the DE-70 or to another peripheral. Check the port of each device in Settings › Devices and of each peripheral in the other tabs of Settings › Peripherals.
Nothing could be asked on …: another program is holding these ports.Close the other program that uses the port, or restart the computer, and tap Find automatically again.
The port does not appear in Serial portPorts already used by a device or another peripheral are not listed. Connect the adapter, leave Settings › Peripherals and open it again. On Linux, restart the computer if the Smart Safe Client was installed a moment ago.
It stopped answering after its USB cable went into another USB socketThe computer may now give that adapter another port name. Tap Find automatically, choose the result and tap Save. Check the DE-70's port in Settings › Devices too.
Choose which device this is fitted to., Choose a model. or Choose a serial port.Fill in what the message asks for and tap Save.
No devices are registered yet. Add one under Devices first.Add the DE-70 or the Cash Infinity in Settings › Devices first. See Devices
A second UPS cannot be added. Edit this one instead.One UPS serves the whole installation. Change the one that is there.
Could not save the peripheralRead the rest of the message, correct what it says and save again. If it continues, open a ticket with a photo of the screen.
The peripheral was taken out of the safeUntick Fitted and in use (or tap Remove) and tap Save. Otherwise the Smart Safe Client keeps waiting for it and blocks the operations.
The Maintenance screen has no Peripherals tabThe tab appears only when the device has a sensor board, a shutter or the UPS saved with Fitted and in use ticked. The OCR does not count.
A test in Maintenance › Peripherals is grayed outThe tests only work while the peripheral says Connected. Check its cable and power, and wait a few seconds.

Sensor board (ACEN BMZ103-RC)

Before a deposit, a manual deposit, a collection or a note count, the Smart Safe Client reads the sensors. If something is wrong, the screen shows Attention with the reason and, when the operator can solve it, what to do.

ProblemWhat to do
The sensor board is not respondingIt blocks every operation of the device, and the safe's lock is not released for a collection. Check the board's power and its cable. In Maintenance › Peripherals, wait for Connected: the Smart Safe Client tries again on its own. If it does not come back, check its port in Settings › Peripherals and open a ticket
The safe door is open and Close and lock the door, then start again.Close and lock the safe's door, then start the operation again.
The safe lock is released and Close and lock the door, then start again.Close the door and let the lock close, then start again.
The depositor module is not seated and Seat the module, then start again.Push the DE module fully into place, then start again.
The banknote pouch is missing and Fit the pouch, then start again.Fit the pouch. Only the deposit stops: a manual deposit and a collection still work.
The guillotine shutter is open and Close it, then start again.Close the guillotine. Deposits and manual deposits stop; a collection still works.
The ink staining system has been triggered or The vibration sensor has been triggeredThe operator cannot clear these. Deposits and manual deposits stop; a collection still works. Check the safe and open a ticket with a photo of Maintenance › Peripherals.
The cabinet temperature is out of range or The sidecar is not in its expected stateOnly the deposit stops. Wait a little and try again. If it continues, open a ticket with a photo of Maintenance › Peripherals.
A sensor cannot be readThe board answers but one of its channels does not. Every operation of the device stops. Open a ticket with a photo of Maintenance › Peripherals, where that channel says Unknown.
In Maintenance › Peripherals, Ink staining or Vibration says OPENThat is normal for these two channels. The word is what the board reports; the colour says whether it is right (green) or wrong.
A channel does not change when you open or close the door, the lock or the pouchUse the Lock and door test in Maintenance › Peripherals and watch each step. If a step never ticks, the sensor or its wiring has a problem: open a ticket with a photo. See Testing the peripherals
A deposit ended by itself: Ended early: a safe sensor was not as expected.A sensor changed while notes were going in. The money counted until then was kept and recorded. Check the safe before the next deposit. On the Reports screen, the Ended early filter shows these operations.
The safe door was opened during this operation and The operation continues. This has been recorded.It is a notice: the opening is recorded in the operation's details, under Sensor events during this operation, where it can be seen later.

The guided collection of the DE-70

With a sensor board, the DE-70's collection is guided: each step ticks itself when the sensors see it, and the line below the steps says what the screen is waiting for. See With a sensor board

ProblemWhat to do
Waiting for the safe lock to release. does not move onThe board releases the lock. Check that the sensor board says Connected in Maintenance › Peripherals.
The safe lock would not release. Nothing was collected and the equipment was not touched — check the sensor board connection and try again.Check the board's cable and power, wait for Connected and start the collection again. The Lock and door test in Maintenance › Peripherals shows whether the lock works.
Open the safe door to continue. stays on screen, but the door is openThe sensors do not see the door. In Maintenance › Peripherals, Vault door must change to OPEN when the door opens. If it does not, open a ticket
Remove the pouch to continue.Take the full pouch out of the safe.
Waiting for an empty pouch to be fitted.Put an empty pouch in its place: without it, the device takes no more deposits.
Close the safe door to continue.Close the door all the way.
Waiting for the safe to lock again.Wait for the lock to close. If it does not close, check the door and open a ticket
The button The sensors stopped responding appearsThe board stopped answering in the middle of the collection. Tap the button: the screen explains what was recorded, and the device stays on hold until a manager reconciles it. Check that the safe is closed and locked. See Reconciliation
The button The pouch was not removed appearsThe door was closed again with the pouch still inside. Tap the button: Collection not performed, nothing is recorded as collected, and the device stays on hold until a manager reconciles it. See Reconciliation

UPS (SMS, Ragtech NSV600)

ProblemWhat to do
The UPS is not respondingIt blocks every operation, on every device. Check that the UPS is on and that its cable is connected, then check its Model and Serial port in Settings › Peripherals › UPS (Find automatically finds it).
The UPS is saved as SMS (HID) and never answersThe Smart Safe Client does not connect to a UPS saved with this model, so it stays Not responding and blocks everything. On Linux, choose SMS (serial) instead: the computer shows that UPS as a serial port, and Find automatically finds it. On Windows, untick Fitted and in use, tap Save and open a ticket
The UPS battery is critically lowDeposits, manual deposits and note counts stop until the battery recovers. Bring back the mains power and let the UPS charge.
Running on UPS battery — a collection opens the safe and must not start without mains powerThere is no mains power: collections stop until it comes back. Bring back the mains power and start again.
Running on UPS battery (a warning, not a stop)Deposits still start. Bring back the mains power as soon as you can.
Mains power was lost during this operationIt is a notice: it is recorded on the operation. Bring back the mains power.
A deposit ended by itself: Ended early: the UPS battery is critically low and the machine could stop mid-count.The money counted until then was kept and recorded. Bring back the mains power before the next deposit.
The Mains transfer test says Timed out: not every step happened.Follow the instructions within the time: pull the UPS's plug from the mains, wait until Transferred ticks, and plug it back in. Then tap Start the test again.
A Ragtech NSV600 shows a reading that is a few seconds oldThat is normal: This model is polled, so a reading is as fresh as the last poll rather than as fresh as the last change.

Shutter (Guillotine, Glory Vertex)

ProblemWhat to do
The shutter is not respondingOnly the deposit stops; a manual deposit and a collection still work. Glory Vertex: check its power, its cable and its Serial port, with Baud rate on Default. Guillotine: its position comes from the sensor board, so check the sensor board.
The shutter is open and Close it, then start again.Close the shutter, then start the deposit again.
The shutter is obstructed and Clear the opening, then start again.Remove what blocks the opening, then start again.
The shutter did not open, so the deposit was cancelled and the notes returned.Give the notes back to the customer. Try Open the shutter and Close the shutter in Maintenance › Peripherals. If it does not move, open a ticket
The shutter did not close. The money was stored; call support before using the machine again.The money is in the safe. Do not use the device and open a ticket
The guillotine was moved. (during a deposit)The guillotine must stay still for the whole deposit. If the message says the deposit was cancelled, the notes were returned; if it says the money was stored, it is in the safe. Check the safe and open a ticket before using the device again.
The shutter's position says UnknownThe Glory Vertex says where it is only when it is driven. In Maintenance › Peripherals, tap Open the shutter and then Close the shutter.
The guillotine has no actuation path: it can be read, not driven.That is normal: the guillotine is moved by hand. It needs the sensor board fitted on the same device.

OCR: the amount from the point of sale (Cash Infinity)

The OCR only fills in the amount on the Payment and Withdraw (by amount) screens of the Cash Infinity. Always compare the amount with the point of sale's screen before you start. See OCR

ProblemWhat to do
The Read the amount from the point of sale button, beside the amount, does not appearIn Settings › Peripherals › OCR, choose that Cash Infinity, choose the Video source, mark Where the amount is on a captured picture (with Several screens, complete every screen), tick Use on the payment and withdraw screens and tap Save. The button appears only on the Payment screen and on the Withdraw screen, by amount.
None of the registered devices pays out money…The OCR exists only for the Cash Infinity: the DE-70 does not use it.
No video source found. Plug in the capture adapter and press Look again.Connect the capture adapter to a USB port and tap Look again. On Linux, if the Smart Safe Client was installed a moment ago, restart the computer first: the permission to use the video adapter takes effect at the next start.
The video source shows (not found now)The adapter is unplugged, or it is in another USB port. Connect it, tap Look again, choose it again and tap Save.
Linux may switch this capture adapter off between readings…, under the Video sourceThe computer was installed before the installer kept the adapter on. Run the installation command again, as HDMI capture adapter explains
On Linux, the point of sale's screen blinks, or the captured picture comes late or blackLinux is switching the capture adapter off between readings. Run the installation command again: see HDMI capture adapter
Could not capture the pictureCheck the adapter's USB cable and that the point of sale sends its picture to the adapter, then tap Capture picture again.
No picture from the point of sale: the adapter is getting no signal, or the screen is off.Turn on the point of sale's screen and check the HDMI cable from the point of sale to the adapter.
Nothing readable in the marked area. or There is no number in the marked area.With the point of sale showing an amount to charge, tap Capture picture and mark again, around the amount only. If the point of sale's screen moves a little, raise Margin (±).
The point of sale's screen is not showing the amount to charge.The marked area does not contain any of the Accepted words (for example TOTAL). Show the amount to charge on the point of sale, or check the words.
The number read is not a valid amount. or The number read is too small to be an amount.Check Decimals on the point of sale's screen: 0 when it shows 27,570, 2 when it shows 1,234.56.
Two readings of the point of sale's screen did not agree: a digit may have been misread.Read again with the point of sale's screen still, or type the amount.
The amount read is 100 times bigger or smaller than the point of sale'sDecimals on the point of sale's screen is wrong: correct it and test with Read now.
The amount read is a little lower than the point of sale'sThat is Round down, in multiples of: it always rounds down, so the customer never pays more. Leave it empty to charge exactly the amount read. With Several screens, each screen has its own Rounding: Down or Up.
The point of sale's screen is none of the screens configured.The POS is showing a screen that is not configured (the change after a sale, an advertisement…). Wait for the screen with the amount and read again. If it was the right screen, check its Texts that identify the screen and their words with Test on this screen's picture.
The Text read shows ? where the POS screen has a letter with an accent (Á, É, Ó, Ç, Ã, Ñ…)That is normal: the OCR reads those letters as ?, and the word is still found, typed with its accents or without them. See Several screens
The amount has the wrong sign for this screen.The screens may be in the wrong order: a refund recognised as a sale, for example. Put the screen with the most specific text first, with Move up. If the order is right, read again: the minus sign may have been misread.
The point of sale's transaction number could not be read for sure.Read again with the POS screen still. If it keeps happening, mark the number again with a little space around it, and fill in After the word when the area holds more than the number.
This picture was recognised as “…”, not as “…”. Check the texts that identify the screens, and their order.The test found another screen first. Check the Texts that identify the screen of both screens and their order.
A message starting with Screen “…”:, when savingThat screen is not complete: open its tab and do what the message says (give the screen a name, mark a text, write its words, name a number…). Then tap Save.
Negative amountLook at the point of sale. If it really shows a negative amount, tap Yes, convert; if not, it was a misread: tap No, discard it and read again.
The amount read is zero.Read again when the point of sale shows the amount to charge, or type it.
Could not read the point of sale's screen (…). Type the amount.Type the amount by hand. Then check the adapter in Settings › Peripherals › OCR with Read now. If it continues, open a ticket
A reading takes a few secondsThat is normal: on a Raspberry Pi a reading of one screen takes 2 to 3 seconds, longer with several screens and transaction numbers; on a desktop computer, under a second.
"Reading the amount on the point of sale's screen — please wait a moment." when tapping the menu or a buttonWhile the amount is being read, the screen and the menu wait for the reading to end. Wait for the amount to appear.
Choose the video source and mark where the amount is., Capture a picture and mark on it where the amount is. or The marked area goes past the picture. Mark it again.Do what the message says, then tap Save.
The rounding has to be an amount greater than zero. or One of the accepted words is empty.Correct Round down, in multiples of (or leave it empty) or Accepted words, then tap Save.

Before opening a ticket

Take a photo of Maintenance › Peripherals with the peripheral open, and open a ticket with it. Attach the logs that come checked in Settings › Support (above all, the Peripheral Logs (sensors, UPS, shutter)), from the day before the problem until today. More about the logs: Which logs to send, and which days

On this page